NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
Correlation Between Bone Density and Angular Deviation of Implants Placed Using CT-Generated Surgical Guides. (Ozan, Oğuz,)
Bibliographical information (record 266611)
Help
Correlation Between Bone Density and Angular Deviation of Implants Placed Using CT-Generated Surgical Guides.
Author:
Ozan, Oğuz, Search Author in Amazon Books

Publisher:
Lippincott Williams & Wilkins,
Edition:
2011.
Classification:
WO 18.2
URL:

http://library.neu.edu.tr:2048/login?url=http://dx.doi.org/10.1097/SCS.0b013e31822e6305
Detailed notes
    - Background: The aim of this study was to evaluate the correlation between the density of bone where implants were placed and the angular deviations that occurred between the virtually planned and actually placed implants using 2 different stereolithographic surgical guides. Methods: The study population consisted of 54 patients who received 216 implants. Computed tomography machine was used for preoperative evaluation of the jawbone for implant therapy as well as determination of the bone density values (Hounsfield units [HU]) of the implantation site. All implant sockets were prepared using 2 different types of stereolithographic surgical guide. Ninety-four implants were installed using the surgical guides (Stentcad Beyond, Ay-Design; Kos-gep, ODTU, Ankara, Turkey) in the mouth, whereas 122 implants were placed after the surgical guides (Stentcad Classic; Kos-gep, ODTU) were removed. Results: The mean bone densities of maxilla and mandible were 561.36 (SD, 229.46) HU and 890.63 (SD, 361.85) HU, respectively. The mean angular deviations between planned and placed implants using Stentcad Classic and Stentcad Beyond surgical guides were 5.32 (SD, 1.96) degrees and 3.73 (SD, 1.14) degrees, respectively. Highly negative correlation was found between the bone density of the placed implant sites and angular deviations in the group in whom implants were installed with freehand. Conclusions: The lower bone density values have resulted in the greater angular deviations in the group, in whom the implants were placed after the surgical guides were removed. This deviation might have been derived from the freehand placement of the implants and the poor quality of the bone.
Related links
Items (1)
Barcode
Status
Library
Section
EOL-1396
Item available
NEU Grand LibraryOnline (WO 18.2 .C67 2011)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.